FC # 7 (motor error) - Climate Wizard CWP-15  

Attached documents:

Fault code diagnosis CW-P15 Pdf

Replacing supply or exhaust fan motor CW-P15 Pdf


 

When diagnosing a FC # 7 on a CW-P it is important to first check what software revision that the CWP-15 has installed. 

Can be checked from the MagIQtouch controller by selecting SETTINGS – COOLER – ABOUT APPLIANCE.

  • Earlier versions of software (pre 420319) FC # 7 indicates a MOTOR ERROR, but did not specify whether it's the Supply or Exhaust fan motor faulty.
  • Software versions 42R0319 and higher has an additional FC # 13 to assist in diagnosing which motor is faulty.


FC # 7 : Indicates a fault with the Supply Fan motor or motor circuit

  • Does the supply fan operate from the service screen for more than 60 seconds?
  • Does the contactor close when the supply is requested to run?
  • Check that 240vac is present on both side of the filter boards

      If all of the above are true, then replace the supply fan.


FC # 13 : Indicates a fault with the Exhaust Fan motor or motor circuit


Regards 

Seeley International 

Technical Support 

Phone:1300 650 399
 

Seeley Service Web Resource is for suitably qualified personnel only and contains a large library of Seeley International Service/Installation/Technical/Training and Spare parts information. Follow the link https://www.seeleyinternational.com/login/ to register

 

Spare Parts Identification follow the link https://spares.seeleyinternational.com/parts