The Braemar Dominator Series™ Series 2 Inverter R32 Ducted system offers flexible configurations to suit different installation and control requirements. This guide explains the available sales options and what is supplied in each kit.

System Type

Choose the system configuration based on installation needs:

Internal Series 2 (KIT085388)

Supplied:
  • Internal Dominator unitKGHV200A1S (installed in ceiling/underfloor; galvanised finish) with safe tray
  • Outdoor condensing unitKCHV160D1B
  • XE71 wired wall control - included as standard with all Dominator Series™ kits (no separate order required)

External Series 2 (KIT085395)

Supplied:
  • External Dominator unitKGHV200A1S (fan/coil assembly housed in an external powder‑coated cabinet)
  • Outdoor condensing unitKCHV160D1B
  • XE71 wired wall control – included as standard with all Dominator Series™ kits (no separate order required)
  • Weather‑protection flashings included with the external cabinet:
    • 655820150 mm KIT FLASHING DOM V2
    • 655845KIT PIPE COVER DOM V2
All external Dominator units are supplied in a powder‑coated finish and include flashings as listed above.

Quick Reference Comparison Table

Feature

Internal Series 2 (KIT085388)

External Series 2 (KIT085395)

Dominator unit cabinet finish

Galvanised sheet metal

Powder‑coated with flashings

Safe tray (internal condensate)

Included

Not applicable (external cabinet)

XE71 wired wall control

Included

Included

Weather protection kits

Not required

Included (655820 & 655845)

Typical installation location

Ceiling/underfloor (indoors)

Outdoor (external cabinet)


Zone Control Options

Enhance comfort and efficiency with zoning:
  • Standard Control: XE71 wired wall control (included in all kits)
  • Optional Zone Control Kit Pt# LE60-13/GH-KIT-B:
    • User touch pad
    • Zone interface (up to 8 zones)
    • 4 RF sensors
    • Power transformer
  • Additional Options:
    • Extra RF sensors Pt# LE60-13/C1-B
    • Wi-Fi module Pt# ME31-00/C13 for app control
    • Subsidiary wired controller Pt# XE70-13/E-B
    • Cable for second controller Pt# 410201060347

3. Accessories

Customize your installation with optional accessories:
  • Air deflectors Outdoor condenser unit Pt# 003049 – 2 required per KCHV160D1B. Description: Directs hot air away from the unit to improve efficiency and comfort
  • Flashing Kit 300mm for external units Pt# 655810. Description: Provides additional weather protection for external installations.
  • Duct connection panels:
    • Oval 400mm: Pt# 655630 (2 required per unit). Description: For oval duct connections, includes etchings for 450 & 500mm.
    • Square 400mm: Pt# 655640 (2 required per unit). Description: For square duct openings.
    • Round 350mm: Pt# 655650 (2 required per unit). Description: For round duct openings.

Reference

For more details, visit the https://www.seeleyinternational.com/product/braemar-dominator-series-reverse-cycle-heating-system/.

Key Notes

  • All Dominator Series kits include XE71 wired wall control as standard.
  • Zoning is optional and requires additional components.
  • External units include weather protection kits by default.