KDHA (ducted indoor) / KCHA (outdoor) comes with the XE7C controller, this has built in Wi-Fi
⚠️ Safety Notice – Reverse Cycle Air Conditioners
This equipment must only be installed, commissioned, serviced and repaired by suitably qualified and licensed personnel.
Before commencing work, complete a task-specific risk assessment and ensure electrical isolation procedures, safe access, adequate service clearances and appropriate PPE have been considered. All work must comply with applicable regulations, standards and manufacturer requirements.
Particular care must be taken when working around electrical systems, refrigerant circuits, moving parts, roof spaces, ceiling spaces, confined spaces and working-at-heights hazards where applicable.
Do not proceed if safe access, required clearances, confined space risks or appropriate safety controls cannot be achieved and maintained.
Safety takes priority over diagnosis, repairs, installation schedules and customer expectations. If the task cannot be completed safely, it must not proceed until the risks have been adequately controlled.
XE7C-24/HC Wi-Fi wired controller

Only adjustable parameter that may need to be changed using the Braemar XE7C/24HC wall control, is the indoor fan static setting: (Factory preset value 5)
YouTube video - setting fan static
Changing the fan static setting on a KDHA single-phase split system can be important for several reasons:
- Optimizing Airflow: Adjusting the fan static setting helps ensure that the airflow is optimal for the specific installation, which can improve the efficiency and comfort of the system.
- Reducing Noise: Proper fan settings can minimize noise levels, making the environment more comfortable.
- Energy Efficiency: Correct fan settings can lead to better energy efficiency, reducing operational costs.
- System Longevity: Proper airflow settings can help prevent strain on the system, potentially extending its lifespan.
To adjust the fan static setting using the XE7C/24HC wall controller, follow these steps:
- MENU
- SET
- Parameter Settings:
- User Parameter:
- Indoor fan pressure: Settable range 1-9 / Default 5